40G QSFP+ SR Transceiver for 150m MMF Links, 850nm MPO8/12
QSFP+40-85-015(SR)-MPO8/12
- Broad Multi-Brand Compatibility
- Flexible Customization Support
- Tested for Reliable Performance
- Fast Response & Delivery
- Professional Technical Support
The FC-LINK QSFP+ 40G 850nm 150m SR MPO 8/12 transceiver features 12-fiber MTP/MPO male connectors, supporting links up to 150m over OM4 MMF and 100m over OM3. It complies with QSFP+ MSA, IEEE 802.3ba 40GBASE-SR4, and supports 4x10GBASE-SR breakout. Fully interoperable with standard 40GBASE-SR4 interfaces, it also offers digital diagnostics via the I2C interface, per QSFP+ MSA specifications, providing real-time access to operating parameters. Its hot-swappable and easy-to-install design makes it perfect for a wide range of applications, including campus networks, data centers, cloud deployments, HPC environments, and interconnections between switches, routers, servers, and transport equipment.
| SPECIFICATIONS | |||
|---|---|---|---|
| Product Model | QSFP+40-85-015(SR)-MPO8/12 | Manufacturer Brand | FC-LINK |
| Package Type | QSFP+ | Optical Connector | MPO 8C/12C |
| Max Data Rate | 40G | Channel Data Rate | 10.3125Gbps |
| Effective transmission distance(OM3) | 100m | Effective transmission distance(OM4) | 150m |
| Wavelength | 850nm | Operating Voltage | 3.3V |
| Fiber Type | MMF | Core Size | 50/125µm |
| Transmitter Type | VCSEL | Receiver Type | PIN |
| TX Power | -7.6~2.4dbm | Receiver Sensitivity | -5.4dbm |
| Digital Diagnostic Monitoring(DDM) | YES | Receiver Overload | 2.4dBm |
| Power Consumption | < 1.5W | Protocols | IEEE 802.3ba IEEE 802.3ae QSFP+ MSA SFF-8436 |
| Operating temperature(Commercial) | 0℃~+70℃ | Storage Temperature(Commercial) | -40℃~+85℃ |
Device Information
| Brand | Spine-layer | Leaf-layer | Port Configuration | Interconnect Interface & Rate | Server-layer | Network Card |
|---|---|---|---|---|---|---|
| Arista | DCS-7050QX-32S-R | DCS-7050TX | 32 x 40GbE QSFP+ | 40G QSFP+ | Service Layer Equipment | Intel X710-DA2、Intel X710-DA4、Intel X710-DA2 OCP 2.0、Mellanox ConnectX-4 Lx、StarTech PEX10GSFP4I、StarTech PEX20000SFPI (x8 Slot)/ Mellanox ConnectX-5(x16 Slot) |
| DCS-7050SX | 32 x 40GbE QSFP+ | 40G QSFP+ | ||||
| DCS-7060CX | 32 x 40GbE QSFP+ | 100G QSFP28(Slow Down) | ||||
| H3C | S9850-32 | S9850 | 32 x 100G QSFP28(Slow Down) | 100G QSFP28(Slow Down) | ||
| S6800-54QF | 32 x 100G QSFP28(Slow Down) | 40G QSFP+ | ||||
| Inspur | CN9420-32C | CN9320 | 32 x 100G QSFP28(Slow Down) | 100G QSFP28(Slow Down) | ||
| CN61108PC-V-H | 32 x 100G QSFP28(Slow Down) | 40G QSFP+ | ||||
| Supermicro | SSE-C3632S | SSE-X3648S | 32 x 100G QSFP28(Slow Down) | 40G QSFP+ | ||
| SSE-G3648B | 32 x 100G QSFP28(Slow Down) | 40G QSFP+ | ||||
| Accton | AS7712-32X | AS5812-54X | 32 x 100G QSFP28(Slow Down) | 40G QSFP+ | ||
| AS7312-54XS | 32 x 100G QSFP28(Slow Down) | 40G QSFP+ | ||||
| Dell | Z9100-ON | S5248F-ON | 32 x 100G QSFP28(Slow Down) | 100G QSFP28(Slow Down) | ||
| Arista | DCS-7060CX-32 | DCS-7060CX | 32 x 400G QSFP-DD(Slow Down) | 100G QSFP28(Slow Down) | ||
| Mellanox/NVIDIA | SN3700C | SN2410C | 32 x 100G QSFP28(Slow Down) | 100G QSFP28(Slow Down) | ||
| SN2100C | 32 x 100G QSFP28(Slow Down) | 100G QSFP28(Slow Down) | ||||
| Cisco | N9K-C9364C-GX | N9K-C93180YC-FX3 | 64 x 100G QSFP28/40G QSFP+ | 100G QSFP28(Slow Down) | ||
| N9K-C9336C-FX2 | 64 x 100G QSFP28/40G QSFP+ | 100G QSFP28(Slow Down) |
Device Information
| Brand | 40G/100G Ethernet Switch | 10G Ethernet Switch | |||
|---|---|---|---|---|---|
| Model | Insertion Port | Model | Insertion Port | Matching Products | |
| Arista | DCS-7050QX-32S-R | 40G QSFP+ | DCS-7050TX | 40G QSFP+ | OSFP+ Optical Transceiver / QSFP+ AOC / QSFP+DAC |
| 40G QSFP+ | DCS-7050SX | 40G QSFP+ | |||
| 40G QSFP+ | DCS-7060CX | 100G QSFP28(Slow Down) | |||
| H3C | S9850-32 | 100G QSFP28(Slow Down) | S9850 | 100G QSFP28(Slow Down) | |
| 100G QSFP28(Slow Down) | S6800-54QF | 40G QSFP+ | |||
| Inspur | CN9420-32C | 100G QSFP28(Slow Down) | CN9320 | 100G QSFP28(Slow Down) | |
| 100G QSFP28(Slow Down) | CN61108PC-V-H | 40G QSFP+ | |||
| Supermicro | SSE-C3632S | 100G QSFP28(Slow Down) | SSE-X3648S | 40G QSFP+ | |
| 100G QSFP28(Slow Down) | SSE-G3648B | 40G QSFP+ | |||
| Accton | AS7712-32X | 100G QSFP28(Slow Down) | AS5812-54X | 40G QSFP+ | |
| 100G QSFP28(Slow Down) | AS7312-54XS | 40G QSFP+ | |||
| Dell | Z9100-ON | 100G QSFP28(Slow Down) | S5248F-ON | 100G QSFP28(Slow Down) | |
| Arista | DCS-7060CX-32 | 400G QSFP-DD(Slow Down) | DCS-7060CX | 100G QSFP28(Slow Down) | |
| Mellanox/NVIDIA | SN3700C | 100G QSFP28(Slow Down) | SN2410C | 100G QSFP28(Slow Down) | |
| 100G QSFP28(Slow Down) | SN2100C | 100G QSFP28(Slow Down) | |||
| Cisco | N9K-C9364C-GX | 100G QSFP28(Slow Down) | N9K-C93180YC-FX3 | 100G QSFP28(Slow Down) | |
| 100G QSFP28(Slow Down) | N9K-C9336C-FX2 | 100G QSFP28(Slow Down) | |||
Device Information
| Brand | 40G/100G Ethernet Switch | 10G Ethernet Switch | Matching Products | ||||
|---|---|---|---|---|---|---|---|
| Model | Insertion Port | Model | Insertion Port | Optical Transceiver | Fiber Optical Patch Cord | Fiber Optical Patch Panel | |
| Arista | DCS-7050QX-32S-R | 40G QSFP+ | DCS-7050TX | 40G QSFP+ | OSFP+ Optical Transceiver / QSFP+ AOC / QSFP+ DAC | MPO-12 to MPO-12 Multimode Patch Cord / LC to LC Singlemode Patch Cord | 1U Fixed Patch Panel |
| 40G QSFP+ | DCS-7050SX | 40G QSFP+ | |||||
| 40G QSFP+ | DCS-7060CX | 100G QSFP28(Slow Down) | |||||
| H3C | S9850-32 | 100G QSFP28(Slow Down) | S9850 | 100G QSFP28(Slow Down) | |||
| 100G QSFP28(Slow Down) | S6800-54QF | 40G QSFP+ | |||||
| Inspur | CN9420-32C | 100G QSFP28(Slow Down) | CN9320 | 100G QSFP28(Slow Down) | |||
| 100G QSFP28(Slow Down) | CN61108PC-V-H | 40G QSFP+ | |||||
| Supermicro | SSE-C3632S | 100G QSFP28(Slow Down) | SSE-X3648S | 40G QSFP+ | |||
| 100G QSFP28(Slow Down) | SSE-G3648B | 40G QSFP+ | |||||
| Accton | AS7712-32X | 100G QSFP28(Slow Down) | AS5812-54X | 40G QSFP+ | |||
| 100G QSFP28(Slow Down) | AS7312-54XS | 40G QSFP+ | |||||
| Dell | Z9100-ON | 100G QSFP28(Slow Down) | S5248F-ON | 100G QSFP28(Slow Down) | |||
| Arista | DCS-7060CX-32 | 400G QSFP-DD(Slow Down) | DCS-7060CX | 100G QSFP28(Slow Down) | |||
| Mellanox/NVIDIA | SN3700C | 100G QSFP28(Slow Down) | SN2410C | 100G QSFP28(Slow Down) | |||
| 100G QSFP28(Slow Down) | SN2100C | 100G QSFP28(Slow Down) | |||||
| Cisco | N9K-C9364C-GX | 100G QSFP28(Slow Down) | N9K-C93180YC-FX3 | 100G QSFP28(Slow Down) | |||
| 100G QSFP28(Slow Down) | N9K-C9336C-FX2 | 100G QSFP28(Slow Down) | |||||
| Absolute Maximum Ratings | |||||||||
| Parameter | Symbol | Min. | Max. | Unit | |||||
| Storage Temperature | TS | -40 | +85 | °C | |||||
| Supply Voltage | VCC | -0.5 | 3.6 | V | |||||
| Operating Relative Humidity | RH | 5 | 85 | % | |||||
| *Exceeding any one of these values may destroy the device immediately. | |||||||||
| Recommended Operating Conditions | |||||||||
| Parameter | Symbol | Min. | Typical | Max. | Unit | ||||
| Operating Case Temperature | Tc | QSFP+40-85-015(SR)-MPO8/12 | 0 | - | +70 | °C | |||
| Power Supply Voltage | Vcc | 3.135 | 3.3 | 3.465 | V | ||||
| Power Supply Current | Icc | - | - | 450 | mA | ||||
| Aggregate Bit Rate | BRAVE | - | 41.25 | - | Gbps | ||||
| Lane Bit Rate | BRLANE | - | 10.3125 | - | Gbps | ||||
| Optical and Electrical Characteristics | |||||||||
| Parameter |
Symbol
|
Min. | Typical | Max. | Unit | ||||
| OM3 MMF |
L
|
0.5 | - | 100 | m | ||||
| Aggregate Bit Rate | BRAVE | - | 40 | - | Gbps | ||||
| Per Lane Bit Rate | BRLANE | - | 10.3125 | - | Gbps | ||||
| Transmitter | |||||||||
| Center Wavelength | λC | 840 | 850 | 860 | nm | ||||
| RMS Spectral Width | RMS | - | - | 0.65 | nm | ||||
| Average Launch Power, Each Lane | Pout/lane | -7.6 | - | 2.4 | dBm | ||||
| Transmit OMA, Per Lane | TX_OMA/lane | -5.6 | - | 3 | dBm | ||||
| Difference in Launch Power Between Any Two Lanes(OMA) | - | - | - | 4 | dB | ||||
| Peak Power, Each Lane | - | - | - | 4 | dBm | ||||
| Transmitter and Dispersion Penalty,Each Lane | TDP/lane | - | - | 3.5 | dB | ||||
| Extinction Ratio | ER | 3 | - | - | dB | ||||
| Optical Return Loss Tolerance | - |
-
|
-
|
12 | dB | ||||
| Average Launch Power of OFF, Each Lane | - | - | - | -30 | dBm | ||||
| Output Optical Eye | IEEE 802.3ba-2010 Compliant | ||||||||
| Receiver | |||||||||
| Center Wavelength | λC | 840 | 850 | 860 | nm | ||||
| Damage Threshold | - | 3.4 | - | - | dB | ||||
| Stressed Receiver Sensitivity in OMA,Each Lane | Pmins | - | - | -5.4 | dBm | ||||
| Maximum Receive Power, Each Lane | Pmax | - | - | 2.4 | dBm | ||||
| Average Power, Each Lane | RX/lane | -9.5 | - | 2.4 | dBm | ||||
| LOS De-Assert, OMA | LOSD | - | - | -7.5 | dBm | ||||
| Receiver Reflectance | Rr | - | - | -12 | dB | ||||
| LOS Assert | LOSA | -30 | - | - | dBm | ||||
| LOS Hysteresis | - | 0.5 | - | - | dB | ||||
| QSFP+ Transceiver Electrical Pad Layout |
| PIN Arrangement and Definition | |||||||||
| Pin | Logic | Symbol |
Description
|
Plug Sequence | Notes | ||||
| 1 | - | GND |
Ground
|
1 | 1 | ||||
| 2 | CML-I | Tx2n | Transmitter Inverted Data Input | 3 | - | ||||
| 3 | CML-I | Tx2p | Transmitter Non-Inverted Data Input | 3 | - | ||||
| 4 | - | GND | Ground | 1 | 1 | ||||
| 5 | CML-I | Tx4n | Transmitter Inverted Data Input | 3 | - | ||||
| 6 | CML-I | Tx4p | Transmitter Non-Inverted Data Input | 3 | - | ||||
| 7 | - | GND | Ground | 1 | 1 | ||||
| 8 | LVTTL-I | ModSelL | Module Select | 3 | - | ||||
| 9 | LVTTL-I | ResetL | Module Reset | 3 | - | ||||
| 10 | - | VccRx | +3.3V Power Supply Receiver | 2 | 2 | ||||
| 11 | LVCMOS- I/O | SCL | 2-wire Serial Interface Clock | 3 | - | ||||
| 12 | LVCMOS- I/O | SDA | 2-wire Serial Interface Data | 3 | - | ||||
| 13 | - | GND |
Ground
|
1 | 1 | ||||
| 14 | CML-O | Rx3p | Receiver Non-Inverted Data Output | 3 | - | ||||
| 15 | CML-O | Rx3n |
Receiver Inverted Data Output
|
3 | - | ||||
| 16 | - | GND | Ground | 1 | 1 | ||||
| 17 | CML-O | Rx1p | Receiver Non-Inverted Data Output | 3 | - | ||||
| 18 | CML-O | Rx1n | Receiver Inverted Data Output | 3 | - | ||||
| 19 | - | GND | Ground | 1 | 1 | ||||
| 20 | - | GND | Ground | 1 | 1 | ||||
| 21 | CML-O | Rx2n | Receiver Inverted Data Output | 3 | - | ||||
| 22 | CML-O | Rx2p | Receiver Non-Inverted Data Output | 3 | - | ||||
| 23 | - | GND | Ground | 1 | 1 | ||||
| 24 | CML-O | Rx4n | Receiver Inverted Data Output | 3 | - | ||||
| 25 | CML-O | Rx4p | Receiver Non-Inverted Data Output | 3 | - | ||||
| 26 | - | GND | Ground | 1 | 1 | ||||
| 27 | LVTTL-O | ModPrsL | Module Present | 3 | - | ||||
| 28 | LVTTL-O | IntL | Interrupt | 3 | - | ||||
| 29 | - | VccTx | +3.3V Power supply transmitter | 2 | 2 | ||||
| 30 | - | Vcc1 | +3.3V Power supply | 2 | 2 | ||||
| 31 | LVTTL-I | LPMode | Low Power Mode | 3 | - | ||||
| 32 | - | GND | Ground | 1 | 1 | ||||
| 33 | CML-I | Tx3p | Transmitter Non-Inverted Data Input | 3 | - | ||||
| 34 | CML-I | Tx3n | Transmitter Inverted Data Input | 3 | - | ||||
| 35 | - | GND | Ground | 1 | 1 | ||||
| 36 | CML-I | Tx1p | Transmitter Non-Inverted Data Input | 3 | - | ||||
| 37 | CML-I | Tx1n | Transmitter Inverted Data Input | 3 | - | ||||
| 38 | - | GND | Ground | 1 | 1 | ||||
| 1: GND is the symbol for signal and supply (power) common for the QSFP+ module. All are common within the QSFP+ module and all module voltages are referenced to this potential unless otherwise noted. Connect these directly to the host board signal-common ground plane. | |||||||||
| 2: Vcc Rx, Vcc1 and Vcc Tx are the receiver and transmitter power supplies and shall be applied concurrently. Vcc Rx Vcc1 and Vcc Tx may be internally connected within the QSFP+ Module in any combination. The connector pins are each rated for a maximum current of 500mA. | |||||||||

Performance Testing
Each module is tested before shipment to help ensure stable optical and electrical performance.

Compatibility Verification
Compatibility validation is available for major switch and router platforms.

Reliability Screening
Selected products support aging, temperature cycle, and stability testing for demanding applications.

Traceable Quality Control
Inspection and production records support more consistent quality control and batch traceability.