100M SFP FX Transceiver for 2km MMF Links, 1310nm Duplex LC

SFP-0155-13-2-LCD-MM

Category: Tags: , , , , , Brand:
  • Broad Multi-Brand Compatibility
  • Flexible Customization Support
  • Tested for Reliable Performance
  • Fast Response & Delivery
  • Professional Technical Support

The FC-LINK SFP 155M 1310nm LC DX MM Transceiver series is a compact, small form-factor pluggable module designed for duplex optical data communication, supporting applications such as Fast Ethernet and OC-3/STM-1 SDH/SONET. Equipped with a 20-pin SFP connector, it enables hot-plug functionality for easy installation and maintenance. Optimized for multi-mode fiber, this transceiver operates at a standard wavelength of 1310nm.The transmitter section features a high-performance multiple quantum well 1310nm laser, compliant with Class 1 laser safety standards under IEC 60825. On the receiver side, the module incorporates an advanced optical detection system, including an integrated GaAs detector preamplifier (IDP) mounted in an optical header and a precision limiting post-amplifier IC, ensuring reliable signal reception and processing.The SFP 155M 1310nm 2km LC DX MM Transceiver series is fully compliant with the SFF-8472 SFP Multi-Source Agreement (MSA), ensuring industry-standard compatibility and interoperability for seamless integration into network systems.

SPECIFICATIONS
Product ModelSFP-0155-13-2-LCDManufacturer BrandFC-LINK
Package TypeSFPOptical ConnectorDuplex LC
Max Data Rate≤ 155MbpsChannel Data Rate-
Effective Transmission Distance2KM
Wavelength1310nmOperating Voltage3.3V
Fiber TypeMMFCore Size50/125
62.5/125
Transmitter TypeFPReceiver TypeIDP
TX Power-19~-14dbmReceiver Sensitivity-31dBm
Digital Diagnostic Monitoring(DDM)YESReceiver Overload-12dBm
Power Consumption<1WProtocolsSFP MSA SFF-8472
Operating temperature(Commercial)0℃~+70℃Storage Temperature(Commercial)-40℃~+85℃
Operating temperature(Industrial)-40℃~+85℃Storage Temperature(Industrial)-40℃~+85℃
Server-to-Switch Data Center Links

Used for 10G/25G/100G optical uplinks between servers and top-of-rack switches in high-density data center deployments.

Building-to-Building Campus Backbone

Suitable for 1G/10G fiber links between office buildings, campus distribution rooms, and backbone aggregation points.

Access-to-Core Enterprise Uplinks

Designed for switch uplinks from access to aggregation or core layers in enterprise and campus network architectures.

Industrial Switching in Harsh Environments

Applied in industrial Ethernet, automation systems, and outdoor cabinets where wider temperature tolerance and stable fiber communication are required.


网络拓扑展示模块
1
1
1

Compatible Brands

Customization Options

Vendor Coding
Private Label
Custom Part Number
Packaging Design
Temperature Grade Selection
Absolute Maximum Ratings
Parameter Symbol Min. Max. Unit
Storage temperature TS -4.0  +85 
Supply voltage VCC -0.5  3.6  V
Operating relative humidity - - 95  %
Exceeding any one of these values may destroy the device immediately

Recommended Operating Environment
Parameter Symbol Min Typical Max Unit
Operating case temperature Tc SFP-0155-13-2-LCD 0 - +70  °C
-40 - +85 
Power supply voltage Vcc 3.15 3.3 3.45 V
Power supply current Icc - - 300 mA
Date rate OC-3/STM-1 - - 155 - Mbps
100M - - 100 -

Performance Specifications – Electrical
Parameter Symbol Min. Typ. Max. Unit Notes
Transmitter
LVPECL inputs(Differential) Vin 500 - 2000 mVpp AC coupled inputs
Input impedance (Differential) Zin 85 100 115 ohm Rin > 100  kohm @ DC
TX_disable Disable - 2 - Vcc+0.3 V -
Enable - 0 - 0.8 -
TX_FAULT Fault - 2 - Vcc+0.3 V -
Normal - 0 - 0.5 -
Receiver
LVPECL outputs (Differential) Vout 400 - 2000 mVpp AC coupled output
Output impedance (Differential) Zout 85 100 115 ohms -
RX_LOS LOS - 2 - Vcc+0.3 V -
Normal - 0 - 0.8 V -
MOD_DEF ( 0:2 ) VoH 2.5 - - V With serial ID
VoL 0 - 0.5 V

Optical and Electrical Characteristics
Parameter Symbol Min. Typical Max. Unit
Distance L - 2 - Km
Data rate - - 100/155 - Mbps
Transmitter
Center wavelength λC 1260 1310 1360 nm
Spectral width (RMS) Δλ - - 4 nm
Average output power Pout -19 - -14 dBm
Extinction ratio ER 10 - - dB
Rise/Fall time(20%~80%) tr/tf - - 2 ps
Total jitter TJ - - 1 UI
Output optical eye Telcordia GR-253-CORE and IUT-T G.957 Compliant
TX disable assert time t_off - - 10 us
Receiver
Center wavelength λC 1260 - 1600 nm
Receiver sensitivity Pmin - - -31 dBm
Receiver overload Pmax -12 - - dBm
Return loss - 14 - - dB
LOS de-assert LOSD - - -32 dBm
LOS assert LOSA -45 - - dBm
LOS hysteresis - 0.5 - - dB

FUNCTIONAL DESCRIPTION OF TRANSCEIVER

SFP TRANSCEIVER ELECTRICAL PAD LAYOUT

PIN FUNCTION DEFINITIONS
Pin Name Function Plug Seq. Notes
1 VeeT Transmitter ground 1 -
2 TX fault Transmitter fault indication 3 1)
3 TX disable Transmitter disable 3 2) Module disables on high or open
4 MOD-DEF2 Module definition 2 3 3) Data line for serial ID.
5 MOD-DEF1 Module definition 1 3 3) Clock line for serial ID.
6 MOD-DEF0 Module definition 0 3 3) Grounded within the module.
7 Rate select Not connect 3 Function not available
8 LOS Loss of signal 3 4)
9 VeeR Receiver ground 1 5)
10 VeeR Receiver ground 1 5)
11 VeeR Receiver ground 1 5)
12 RD- Inv. received data out 3 6)
13 RD+ Received data out 3 6)
14 VeeR Receiver ground 1 5)
15 VccR Receiver power 2 7) 3.3V ± 5%
16 VccT Transmitter power 2 7) 3.3V ± 5%
17 VeeT Transmitter ground 1 5)
18 TD+ Transmit data In 3 8)
19 TD- Inv. transmit data In 3 8)
20 VeeT Transmitter ground 1 5)
Notes:
1) TX Fault is an open collector/drain output, which should be pulled up with a 4.7K – 10KΩ resistor on the host board. Pull up voltage between 2.0V and VccT/R+0.3V. When high, output indicates a laser fault of some kinds. Low indicates normal operation. In the low state, the output will be pulled to < 0.8V.

2) TX disable is an input that is used to shutdown the transmitter optical output. It is pulled up within the module with a 4.7K – 10 KΩ resistor. Its states are:
Low (0 – 0.8V): Transmitter on
 (>0.8, < 2.0V): Undefined
High (2.0 – 3.465V): Transmitter Disabled
Open: Transmitter Disabled

3) Mod-Def 0,1,2. These are the module definition pins. They should be pulled up with a 4.7K – 10K resistor on the host board. The pull-up voltageshall be VccT or VccR .
Mod-Def 0 is grounded by the module to indicate that the module is present
Mod-Def 1 is the clock line of two wire serial interface for serial ID
Mod-Def 2 is the data line of two wire serial interface for serial ID

4) LOS is an open collector/drain output, which should be pulled up with a 4.7K – 10KΩ resistor. Pull up voltage between 2.0V and VccT/R+0.3V. When high, this output indicates the received optical power is below the worst-case receiver sensitivity (as defined by the standard in use).Low indicates normal operation. In the low state, the output will be pulled to < 0.8V.

5) VeeR and VeeT may be internally connected within the SFP module.

6) RD-/+: These are the differential receiver outputs. They are AC coupled 100Ω differential lines which should be terminated with 100Ω (differential) at the user SERDES. The AC coupling is done inside the module and is thus not required on the host board. The voltage swing on these lines will be between 400 and 2000 mV differential (200 –1000 mV single ended) when properly terminated.

7) VccR and VccT are the receiver and transmitter power supplies. They are defined as 3.3V ±5% at the SFP connector pin. Maximum supply current is 300Ma. Recommended host board power supply filtering is shown below. Inductors with DC resistance of less than 1ohm should be used in order to maintain the required voltage at the SFP input pin with 3.3V supply voltage. When the recommended supply-filtering network is used, hot plugging of the SFP transceiver module will result in an inrush current of no more than 30Ma greater than the steady state value.VccR and VccT may be internally connected within the SFP transceiver module.

8) TD-/+: These are the differential transmitter inputs. They are AC-coupled, differential lines with 100Ω differential termination inside the module. The AC coupling is done inside the module and is thus not required on the host board. The inputs will accept differential swings of 400 – 2000mV (200 – 1000mV single-ended).
Performance Testing

Each module is tested before shipment to help ensure stable optical and electrical performance.

Compatibility Verification

Compatibility validation is available for major switch and router platforms.

Reliability Screening

Selected products support aging, temperature cycle, and stability testing for demanding applications.

Traceable Quality Control

Inspection and production records support more consistent quality control and batch traceability.