The FC-LINK QSFP-DD 400G 850nm SR8 MPO16 Transceiver is an 8-Channel,Pluggable,Fiber-Optic QSFP-DD for 400Gbps SR8 Applications.It is a high performance module for short-range data communication and interconnectapplications which operate at 53.125Gbps per lane up to 70m using OM3 fiber and 100m using OM4 fiber.The optical interface uses MPO receptacles. This module is designed to operate over multimode fiber systems using a nominal wavelengthof 850nm.The electrical interface uses a76 contact edge type connector.
| SPECIFICATIONS | |||
|---|---|---|---|
| Product Model | QSFPDD-400-85-01(SR8)-MPO16 | Manufacturer brand | FC-LINK |
| Package Type | QSFPDD | Optical connector | MPO 16C/24C |
| Max Data Rate | 400Gbps | Channel Data Rate | 53.125Gbps |
| Effective transmission distance(OM3) | 70m | Effective transmission distance(OM4) | 100m |
| Wavelength | 850nm | Operating voltage | 3.3V |
| Fiber Type | MMF | Core Size | 50/125 |
| Transmitter Type | VCSEL | Receiver Type | PIN |
| TX Power | -6.5~4.0dBm | Receiver Sensitivity | -6.5dBm |
| Digital Optical Monitoring(DOM) | YES | Receiver Overload | 4dBm |
| Power Consumption | <12W | Protocols | 400G BASE-SR8 Ethernet |
| Operating temperature(Commercial) | 0℃~+70℃ | Storage Temperature(Commercial) | -40℃~+85℃ |

Server-to-Switch Data Center Links
Used for 10G/25G/100G optical uplinks between servers and top-of-rack switches in high-density data center deployments.

Building-to-Building Campus Backbone
Suitable for 1G/10G fiber links between office buildings, campus distribution rooms, and backbone aggregation points.

Access-to-Core Enterprise Uplinks
Designed for switch uplinks from access to aggregation or core layers in enterprise and campus network architectures.

Industrial Switching in Harsh Environments
Applied in industrial Ethernet, automation systems, and outdoor cabinets where wider temperature tolerance and stable fiber communication are required.
| Absolute Maximum Ratings | |||||||||
| Parameter | Symbol | Min. | Max. | Unit | |||||
| Power supply voltage | VCC | -0.5 | 3.6 | V | |||||
| Storage temperature | TC | -40 | 85 | ℃ | |||||
| Relative humidity | RH | 0 | 85 | % | |||||
| These values represent the damage threshold of the module.Stress in excess of any of the individual absolute maximum ratingscan cause immediate catastrophic damage to the module even if all other parameters are within recommended operating conditions. | |||||||||
| Recommended Operating Environment | |||||||||
| Parameter | Symbol | Min | Typical | Max | Unit | ||||
| Power supply voltage | VCC | 3.15 | 3.3 | 3.45 | V | ||||
| Operating case temperature | Tca | 0 | - | 70 | ℃ | ||||
| Recommended operating environment specifies parameters for which the electrical and optical characteristics hold unless otherwise noted. | |||||||||
| Electrical Characteristics | |||||||||
| Parameter | Symbol | Min | Typical | Max | Unit | Notes | |||
| Data rate per lane | DR | - | 53.125 | - | Gbps | - | |||
| Transmitter | |||||||||
| Single ended output voltage tolerance | - | -0.3 | - | 4 | V | - | |||
| Common mode voltage tolerance | - | 15 | - | - | mV | - | |||
| Input differential impedance | Rin | - | 100 | - | Ω | - | |||
| Differential input voltage swing | Vin | 300 | - | 1100 | mV | - | |||
| Tx fault | VoL | -0.3 | - | 0.4 | V | At 0.7mA | |||
| Receiver | |||||||||
| Single ended output voltage tolerance | - | -0.3 | - | 4 | V | - | |||
| Differential output swing | Vout | 300 | - | 900 | mV | - | |||
| Output differential impedance | Rout | - | 100 | - | Ω | - | |||
| The following electrical characteristics are defined over the recommended operating environment unless otherwise specified. | |||||||||
| Optical Characteristics | |||||||||
| Parameter | Symbol | Min | Typical | Max | Unit | Notes | |||
| Transmitter | |||||||||
| Center wavelength | λ | 820 | 850 | 880 | nm | - | |||
| RMS spectral width | Pm | - | - | 0.6 | nm | 1 | |||
| Average optical power | Po | -6.5 | - | 4 | dBm | 2 | |||
| Extinction ratio | ER | 3 | - | - | dBm | - | |||
| Optical modulation amplitude | OMA | -4.5 | - | 3 | dB | - | |||
| Transmitter and dispersion eye closure | TDECQ | - | - | 4.5 | dB | - | |||
| Optical return loss tolerance | ORL | - | - | 12 | dB | - | |||
| Receiver | |||||||||
| Center wavelength | λ | 820 | - | 880 | nm | - | |||
| Average receive power,each lane | - | -8.4 | - | 4 | dBm | - | |||
| Receive power(OMAouter),each lane | - | - | - | 3 | dBm | - | |||
| Receiver sensitivity(OMAAut) | Psens | - | - | -6.5 | dBm | 3 | |||
| LOS asserted | Lsa | -30 | - | - | dBm | - | |||
| LOS De-asserted | Lda | - | - | -10 | dBm | - | |||
| LOS hysteresis | Lh | 0.5 | - | - | dB | - | |||
| Note: [1]Trade-offs are available between spectral width,center wavelength and minimum OMA. [2]The optical power is launched into MMF [3]BER=2.4E-4;PRBS310@26.5625GBd. | |||||||||
| QSFP-DD Transceiver Electrical Pad Layout |
| Pin Definition | |||||||||
| Pin | Symbol | Name/Description | |||||||
| 1 | GND | Ground | |||||||
| 2 | Tx2n | Transmitter inverted data input | |||||||
| 3 | Tx2p | Transmitter non-inverted data input | |||||||
| 4 | GND | Ground | |||||||
| 5 | Tx4n | Transmitter inverted data input | |||||||
| 6 | Tx4p | Transmitter non-inverted data input | |||||||
| 7 | GND | Ground | |||||||
| 8 | ModSelL | Module select | |||||||
| 9 | ResetL | Module reset | |||||||
| 10 | Vcc Rx | +3.3V Power supply receiver | |||||||
| 11 | SCL | 2-wire serial interface clock | |||||||
| 12 | SDA | 2-wireserial interface data | |||||||
| 13 | GND | Ground | |||||||
| 14 | Rx3p | Receiver non-inverted data output | |||||||
| 15 | Rx3n | Receiver inverted data output | |||||||
| 16 | GND | Ground | |||||||
| 17 | Rx1p | Receiver non-inverted data output | |||||||
| 18 | Rx1n | Receiver inverted data output | |||||||
| 19 | GND | Ground | |||||||
| 20 | GND | Ground | |||||||
| 21 | Rx2n | Receiver onverted data output | |||||||
| 22 | Rx2p | Receiver non-inverted data output | |||||||
| 23 | GND | Ground | |||||||
| 24 | Rx4n | Receiver inverted data output | |||||||
| 25 | Rx4p | Receiver non-onverted data output | |||||||
| 26 | GND | Ground | |||||||
| 27 | ModPrsL | Module present | |||||||
| 28 | IntL | Interrupt | |||||||
| 29 | VCC Tx | +3.3V power supply transmitter | |||||||
| 30 | VCC1 | +3.3V power supply | |||||||
| 31 | InitMode | Initialization mode;In legacy QSFP applications,the InitModepad is called LPMODE | |||||||
| 32 | GND | Ground | |||||||
| 33 | Tx3p | Transmitter non-inverted data input | |||||||
| 34 | Tx3n | Transmitter inverted data input | |||||||
| 35 | GND | Ground | |||||||
| 36 | Tx1p | Transmitter non-Inverted data input | |||||||
| 37 | Tx1n | Transmitter inverted data input | |||||||
| 38 | GND | Ground | |||||||
| 39 | GND | Ground | |||||||
| 40 | Tx6n | Transmitter inverted data input | |||||||
| 41 | Tx6p | Transmitter non-inverted data input | |||||||
| 42 | GND | Ground | |||||||
| 43 | Tx8n | Transmitter inverted data input | |||||||
| 44 | Tx8p | Transmitter non-inverted data input | |||||||
| 45 | GND | Ground | |||||||
| 46 | Reserved | For future use | |||||||
| 47 | VS1 | Module vender specific1 | |||||||
| 48 | Vcc Rx1 | +3.3V power supply receiver | |||||||
| 49 | VS2 | Module vender specific2 | |||||||
| 50 | VS3 | Module vender specific3 | |||||||
| 51 | GND | Ground | |||||||
| 52 | Rx7p | Receiver non-inverted data output | |||||||
| 53 | Rx7n | Receiver inverted data output | |||||||
| 54 | GND | Ground | |||||||
| 55 | Rx5p | Receiver non-inverted data output | |||||||
| 56 | Rx5n | Receiver inverted data output | |||||||
| 57 | GND | Ground | |||||||
| 58 | GND | Ground | |||||||
| 59 | Rx6n | Receiver inverted data output | |||||||
| 60 | Rx6p | ReceiverNon-inverted data output | |||||||
| 61 | GND | Ground | |||||||
| 62 | Rx8n | Receiver inverted data output | |||||||
| 63 | Rx8p | Receiver non-inverted data output | |||||||
| 64 | GND | Ground | |||||||
| 65 | NC | No connect | |||||||
| 66 | Reserved | For futureuse | |||||||
| 67 | VCC Tx1 | +3.3V power supply transmitter | |||||||
| 68 | VCC2 | +3.3V power supply | |||||||
| 69 | Reserved | For future use | |||||||
| 70 | GND | Ground | |||||||
| 71 | Tx7p | Transmitter non-inverted data input | |||||||
| 72 | Tx7n | Transmitter inverted data input | |||||||
| 73 | GND | Ground | |||||||
| 74 | Tx5p | Transmitter non-inverted data input | |||||||
| 75 | Tx5n | Transmitter inverted data input | |||||||
| 76 | GND | Ground | |||||||

Performance Testing
Each module is tested before shipment to help ensure stable optical and electrical performance.

Compatibility Verification
Compatibility validation is available for major switch and router platforms.

Reliability Screening
Selected products support aging, temperature cycle, and stability testing for demanding applications.

Traceable Quality Control
Inspection and production records support more consistent quality control and batch traceability.
Related products
-

40G QSFP+ SR Transceiver for 150m MMF Links, 850nm MPO8/12
QSFP+40-85-015(SR)-MPO8/12
-

Generic Compatible 200GBASE-SR4 QSFP56 850nm 100m DOM MPO8/12 MMF Optical Transceiver Module
QSFP56-200-85-01(SR4)-MPO8/12
-

100M SFP FX Transceiver for 2km MMF Links, 850nm Duplex LC
SFP-0155-85-2-LCD
-

Generic Compatible 400GBASE DR4 OSFP 1310nm 500m DOM MPO8/12 SMF Optical Transceiver Module
OSFP-400(4×100)-13-05(DR4)-MPO8/12