MPO Breakout Cable, 2 x MPO-12 PC/APC(Female/Male) to 2 x MPO-12 PC/APC(Female/Male), 24 Fibers, Multimode(OM4),0.35dB Max, Aqua/Violet

40G QSFP+(UP to 170M)
100G QSFP28(UP to 170M)
200G QSFP56(UP to 100M)
400G QSFPDD/QSFP112 VR4(UP to 50M)
400G QSFPDD SR4.2(UP to 100M)

  • Broad Multi-Brand Compatibility
  • Flexible Customization Support
  • Tested for Reliable Performance
  • Fast Response & Delivery
  • Professional Technical Support
SPECIFICATIONS
Connector A2*MPOConnector B2*MPO
Fiber TypeOM4Fiber Number24 Fibers
MPO ILStandard loss/Low lossPolishingPC or APC
Branching Type2*2Connector Boot TypeRound fiber
Connector TypeFemale/MaleRL≥20dB (MM)
IL(Typical)0.1/0.2dBIL(Max. Value)0.35/0.6dB
Breakout Outside Diameter (OD)2.0/3.0mmCable ColorAqua/Violet
Breakout Length0.3-1.5mFlame Retardant GradeOFN/OFNR/OFNP
Cable MaterialLSZH/PVC/TPUFiber Loss2.4dB@850nm/0.6dB@1300nm
Fiber BrandCorning/YOFCMin.bending Radius(Long Term)20D
Working Wavelength850/1300(MM)Durability≥500 times
Min.bending Radius(Short Term)10DPolarityConsistent with the main cable
Operating Temperature-10 to 70℃ (14 to 158℉)Storage Temperature-40 to 85℃ (-40 to 185℉)

Product Presentation

This 24-Fiber 2 x MPO-12 to 2 x MPO-12 OM4 Multimode Breakout Cable is your strategic tool for maximizing reach and future-proofing your mid-distance backbone. It extends the reliable reach of 40G/100G links (up to 170M) and significantly boosts performance for 200G QSFP56 (up to 100M). Crucially, it provides superior bandwidth for 400G QSFPDD SR4.2 (up to 100M), allowing greater flexibility in switch placement. The high-capacity dual MPO-12 structure ensures minimal insertion loss, guaranteeing optimal signal quality over extended distances with Elite Low Loss (IL Max ≤ 0.35dB) specifications.

MPO Breakout Cable Series Products

Customization Options

Vendor Coding
Private Label
Custom Part Number
Packaging Design
Temperature Grade Selection

Application

QSFP, CFP optical tranceiver
High density data center
FTTX

1
1
1

Performance Parameter

Technical Performance
Ferrule typeInsertion lossReturn loss
TypicalMaximum
SM standard loss0.20dB≤0.75dB≥ 60dB (APC 8°)
SM low loss0.10dB≤0.35dB
MM standard loss0.20dB≤0.6dB≥ 20dB
MM low loss0.10dB≤0.35dB
MT Ferrule Options
Fiber modePerformanceFiber count
Single modeStandard loss12 (1x12)
24 (2x12)
Low loss12 (1x12)
MultimodeStandard loss12 (1x12)
16 (1x16)
24 (2x12)
32 (2x16)
Low loss12 (1x12)
24 (2x12)
Cable Parameter
ItemsSpecifications
Fiber Count24681224
FiberDiameter250±15μm
ColorBlue/Orange/Green/Brown/Gray/White/Red/Black/Yellow/Purple/Pink/Aqua
Strength MemberAramid Yarn
Outer JacketDiameter3.0±0.2mm
MaterialPVC /LSZH
ColorBlue/Orange/Green/Brown/Gray/White/Red/Black/Yellow/Purple/Pink/Aqua
Detail Display

MPO Breakout Cable, 2 x MPO-12 PC/APC(Female/Male) to 2 x MPO-12 PC/APC(Female/Male), 24 Fibers, Multimode(OM4),0.35dB Max, Aqua/Violet
Fiber Optic Cable Structure

Mechanical Performance
ItemsSpecifications
Fiber Count24681224
Tensile Strength (Long Term) / N80
Tensile Strength (Short Term)/ N150
Crush Resistance (Long Term) / N/10cm150100
Crush Resistance (Long Term) / N/10cm500
Min. Bend Radius (Dynamic) / mm20D
Min. Bend Radius (Static)/ mm10D
Operating Temperature/℃-20~+60
Storage Temperature/℃-20~+60
SM Fiber Parameter
ItemsUnitG.652DG.657A1G.657A2
Mode Field Diameter1310nmμm9.1±0.48.8±0.48.8±0.4
1550nmμm10.4±0.59.8±0.59.8±0.5
Cladding Diameterμm125±1125±0.7125±0.7
Cladding Non-Circularity%≤1≤0.7≤0.7
Core-Cladding Concentricity Errorμm≤0.6≤0.5≤0.5
Coating Diameterμm245±7245±5245±5
Coating Non-Circularity%≤6.0≤6.0≤6.0
Cladding-Coating Concentricity Errorμm≤12.0≤12.0≤12.0
Cable Cutoff Wavelengthnmλcc≤1260λcc≤1260λcc≤1260
Cable Attenuation Coefficient1310nmdB/km≤0.4≤0.4≤0.4
1550nmdB/km≤0.3≤0.3≤0.3
MM Fiber Parameter
Itemsunit62.5/12550/125OM3-150OM3-300OM4
Core Diameterμm62.5±2.550±2.550±2.550±2.550±2.5
Cladding Diameterμm125±1.0125±1.0125±1.0125±1.0125±1.0
Core Non-Circularity%≤5.0≤5.0≤5.0≤5.0≤5.0
Cladding Non-Circularity%≤1.0≤1.0≤1.0≤1.0≤1.0
Core-Cladding Concentricity Errorμm≤1.5≤1.5≤1.0≤1.0≤1.0
Coating Diameterμm245±7245±7245±7245±7245±7
Coating Non-Circularity%≤6.0≤6.0≤6.0≤6.0≤6.0
Cladding-Coating Concentricity Errorμm≤12.0≤12.0≤12.0≤12.0≤12.0
OFL Bandwidth850nmMHz·km≥160≥500≥700≥1500≥3500
1300nmMHz·km≥500≥500≥500≥500≥500
Cable Attenuation Coefficient850nmdB/km≤3.0≤3.0≤3.0≤3.0≤3.0
1300nmdB/km≤1.0≤1.0≤1.0≤1.0≤1.0

Production & Testing Equipment

Patch Cord Workshop
Testing Process
SUMIX MAX-QM+ Interferometer
Interferomete Report
Domaille HDC-5300 Polishing Machine
JGR IRL Tester
Polarity Tester
Endface Detection

Quality Advantage

Configuration Information

MPO Breakout Cable产品详情订购信息