The FC-LINK SFP28 BIDI 25G 1270/1330nm 20km ELR LC SX transceiver is a high-performance module designed for bidirectional optical data transmission over single-mode fiber, supporting distances of up to 20km. It complies with SFF-8472, SFF-8402, SFF-8432, and applicable sections of SFF-8431 standards.Equipped with digital diagnostic monitoring via a 2-wire serial interface, as outlined in SFF-8472, this transceiver ensures reliable performance and precise monitoring for seamless integration into high-speed network applications.

SPECIFICATIONS
Product ModelSFP28BD-25-1213-20(ELR)-LCManufacturer BrandFC-LINK
Package TypeSFP28Optical ConnectorLC
Max Data Rate25.78GbpsChannel Data Rate-
Effective Transmission Distance20km
Wavelength1270nm-TX/1330nm-RXOperating Voltage3.3V
Fiber TypeSMFCore Size9/125µm
Transmitter TypeDFB BiDiReceiver TypePIN
TX Power0~6dBmReceiver Sensitivity<-14dBm
Digital Optical Monitoring(DOM)YESReceiver Overload2.5dB
Power Consumption≤1.2WProtocolseCPRI, SFF-8472, SFF-8432, SFF-8431
Operating Temperature(Commercial)0℃~+70℃Storage Temperature(Commercial)-40℃~+85℃
Server-to-Switch Data Center Links

Used for 10G/25G/100G optical uplinks between servers and top-of-rack switches in high-density data center deployments.

Building-to-Building Campus Backbone

Suitable for 1G/10G fiber links between office buildings, campus distribution rooms, and backbone aggregation points.

Access-to-Core Enterprise Uplinks

Designed for switch uplinks from access to aggregation or core layers in enterprise and campus network architectures.

Industrial Switching in Harsh Environments

Applied in industrial Ethernet, automation systems, and outdoor cabinets where wider temperature tolerance and stable fiber communication are required.


网络拓扑展示模块
1
1
1

Compatible Brands

Customization Options

Vendor Coding
Private Label
Custom Part Number
Packaging Design
Temperature Grade Selection
Absolute Maximum Ratings
Parameter Symbol Unit Min. Max.
Storage temperature range TS °C -40  85 
Relative humidity RH % 85 
Supply voltage VCC V -0.3  3.6 

Recommended Operating Conditions
Parameter Symbol Unit Min. Typ. Max.
Operating case temperature range Tc -40 - 85
Power supply voltage VCC V 3.135 3.3 3.465
Bit rate BR Gb/s 24.33024 25.78125 -
Max. supported link length L km 10 20 -

Electrical Characteristics
Parameter Symbol Unit Min. Typ. Max. Note
Supply voltage VCC V 3.14  3.3 3.46  -
Supply current Icc mA - - 360  @3.3V
Transmitter
Input differential impedance Rin Ω - 100 - -
Single ended data input swing VIN mVp-p 90 - 450 -
Transmit disable voltage VDIS V 2 - VCCHOST -
Transmit enable voltage VEN V VEE - VEE+0.8 -
Transmit fault assert voltage VFA V 2.2 - VCCHOST -
Transmitfault de-assert voltage VFDA V VEE - VEE+0.4 -
Receiver
Single ended data output swing VOD mVp-p 200 - 450 -
LOS fault VLOSFT V 2.2 - VccHOST -
LOS normal VLOSNR V VEE - Vee+0.4 -

Optical Characteristics
Parameter Symbol Unit Min. Typ. Max Notes
Transmitter
Center wavelength range λ nm 1320 - 1340 Downstream
- - 1280 Upstream
Spectral width | -20dB - nm - - 1 -
Side mode suppression ratio SMSR dB 30 - - -
Average launch power PAVG dBm 0 - 6 -
OMA launch power POMA dBm -2 - - -
Transmitter and dispersion penalty 25G | BER=5E-5 TDP dB - - 4 -
Average launch power of OFF transmitter POFF dBm - - -30 -
Extinction ratio ER dB 3.5 - - -
RIN20OMA RIN dB/Hz - - -130 -
Optical return loss tolerance - dB - - 20 -
Mask margin - % 5 - - 1
Receiver
Center wavelength λr nm 1260 1270 1280 Downstream
1320 1330 1340 Upstream
Overload - dBm 2.5 - - -
OMA receiver sensitivity up to 25G 5E-5 POMA dBm - - -14 -
LOS de-assert LOSA dBm -30 - - -
Los assert LOSD dBm - - -17 -
Los hysteresis - dB 0.5 - - -
Note 1: Template: {0.31, 0.40, 0.45, 0.34, 0.38, 0.40}, Hit Ratio: 5E-5

Pin Function Definitions

TRANSCEIVER PIN DESCRIPTIONS
Pin No. Symbol Logic Description
VeeT - Connected to signal ground on the host board.
TX fault LVTTL output Module transmitter fault output
TX disable LVTTL input Module transmitter disable control
SDA LVTTL input/output 2-wire serial interface data
SCL LVTTL input/output 2-wire serial interface clock
MOD_ABS - Module absent (connected to Module ground)
RS0 LVTTL input Rate select 0 (Rx): Low=CDR Bypass; high=CDR select
LOS LVTTL output Receiver loss of signal
RS1 LVTTL input Rate select 1 (Tx): Low=CDR Bypass; high=CDR select
10,11,14 VeeR - Connected to signal ground on the host board.
12  RD- CML output Receiver inverted data output, internally AC coupled and terminated.
13  RD+ CML output Receiver non-inverted data output, internally AC coupled and terminated.
15  VccR - Receiver power 3.3V supply
16  VccT - Transmitter power 3.3V supply
18  TD+ CML input Transmitter non-inverted data input, internally AC coupled and terminated.
19  TD- CML input Transmitter inverted data Input, internally AC coupled and terminated

Performance Testing

Each module is tested before shipment to help ensure stable optical and electrical performance.

Compatibility Verification

Compatibility validation is available for major switch and router platforms.

Reliability Screening

Selected products support aging, temperature cycle, and stability testing for demanding applications.

Traceable Quality Control

Inspection and production records support more consistent quality control and batch traceability.

光模块产品详情订购信息---SFP28