10G SFP+ BIDI ZR Transceiver for 80km SMF Links, 1490/1550nm Simplex LC

SFP+BD-10-1415-80(ZR)-LC

  • Broad Multi-Brand Compatibility
  • Flexible Customization Support
  • Tested for Reliable Performance
  • Fast Response & Delivery
  • Professional Technical Support

The FC-LINK SFP+ BIDI 10G 1490/1550nm 80km ZR LC SX single-mode transceiver is a compact, pluggable module designed for duplex optical data communication, including IEEE 802.3ae 10GBASE-LR/LW applications. It features an SFP+ 20-pin connector for hot-plug capability and is optimized for single-mode fiber, operating at a nominal wavelength of either 1490nm or 1550nm. The transmitter section employs a multiple quantum well DFB laser, compliant with Class 1 laser safety standards per IEC-60825. The receiver integrates an InGaAs detector preamplifier (IDP) within an optical header, along with a limiting post-amplifier IC for efficient signal processing.

SPECIFICATIONS
Product ModelSFP+BD-10-1415-80(ZR)-LCManufacturer BrandFC-LINK
Package TypeSFP+ BIDIOptical ConnectorDuplex LC
Max Data Rate11.3GbpsChannel Data Rate10.3125Gbps
Effective Transmission Distance80km
WavelengthTx:1490nm/Rx:1550nm
Tx:1550nm/Rx:1490nm
Operating Voltage3.3V
Fiber TypeSMFCore Size9/125µm
Transmitter TypeEMLReceiver TypeIDP
TX Power-1~4dBmReceiver Sensitivity-20dBm,-23dBm
Digital Diagnostic Monitoring(DDM)YESReceiver Overload-6dBm
Power Consumption<2.0WProtocolsSFP+ MSA
SFF-8431
SFF-8472
Operating Temperature(Commercial)0℃~+70℃Storage Temperature(Commercial)-40℃~+85℃
Server-to-Switch Data Center Links

Used for 10G/25G/100G optical uplinks between servers and top-of-rack switches in high-density data center deployments.

Building-to-Building Campus Backbone

Suitable for 1G/10G fiber links between office buildings, campus distribution rooms, and backbone aggregation points.

Access-to-Core Enterprise Uplinks

Designed for switch uplinks from access to aggregation or core layers in enterprise and campus network architectures.

Industrial Switching in Harsh Environments

Applied in industrial Ethernet, automation systems, and outdoor cabinets where wider temperature tolerance and stable fiber communication are required.


网络拓扑展示模块
1
1
1

Compatible Brands

Customization Options

Vendor Coding
Private Label
Custom Part Number
Packaging Design
Temperature Grade Selection
Absolute Maximum Ratings
Parameter Symbol Min. Max. Unit
Storage temperature TS -40  +85  °C
Supply voltage VCC -0.5  3.6  V
Operating relative humidity RH 5.0  95.0  %
*Note: Exceeding any one of these values may destroy the device permanently.

Recommended Operating Conditions
Parameter Symbol Min. Typical Max. Unit
Power supply voltage Vcc 3.15  3.3  3.45  V
Power supply current Icc - - 606  mA
Operating case temperature Tc - 0 70  °C

Performance Specifications–Electrical
Parameter Symbol Min. Typ. Max Unit Notes
Transmitter
CML inputs(Differential) Vin 150 - 1200 mVpp AC coupled inputs
Input impedance (Differential) Zin 85 100 115 ohm Rin > 100 kohms @ DC
Tx_DISABLE input voltage - high - 2 - Vcc+0.3 V -
Tx_DISABLE input voltage - low - 0 - 0.8 V -
Tx_FAULT output voltage - high - 2 - Vcc+0.3 V Io = 400µA; Host Vcc
Tx_FAULT output voltage - low - 0 - 0.5 V Io = -4.0mA
Receiver
CML outputs (Differential) Vout 120 - 800 mVpp AC coupled outputs
Output impedance (Differential) Zout 85 100 115 ohms -
Rx_LOS output voltage - high - 2 - 0.5 V lo = 400µA; Host Vcc
Rx_LOS output voltage - low - 0 - 700 mVpp lo = -4.0mA
MOD_DEF ( 2:0 ) VoH 2.5 - - V With Serial ID
VoL 0 - 0.5 V

Optical Characteristics-1490nm EML & APD/TIA
Parameter Symbol Min. Typical Max. Unit
Data rate - - 10.3125 11.3 Gbps
Transmitter
Centre wavelength λC 1480 1490 1500 nm
Spectral width (-20dB) Δλ - - 1 nm
Side mode suppression ratio SMSR 30 - - dB
Average output power Pout, AVG -1 - 4 dBm
Extinction ratio ER 7.5 - - ms
Average power of OFF transmitter - - - -30 dBm
Relative intensity noise RIN - - -128 dB/Hz
Eye mask Compliant with IEEE 802.3ae
Receiver
Centre wavelength λc 1540 - 1565 nm
Sensitivity@10.3125Gbps Pmin - - -23 dBm
Sensitivity(SM 80km) Pmin - - -20 dbm
Receiver overload Pmax -6 - - dBm
LOS De-assert LOSD - - -24 dBm
LOS assert LOSA -38 - - dBm
LOS -hysteresis PHys 0.5 - 8 dB

Optical Characteristics-1550nm EML & APD/TIA
Parameter Symbol Min. Typical Max. Unit
Data rate - - 10.3125 11.3 Gbps
Transmitter
Centre wavelength λC 1540 1550 1560 nm
Spectral width (-20dB) Δλ - - 1 nm
Side mode suppression ratio SMSR 30 - - dB
Average output power Pout, AVG -1 - 4 dBm
Extinction ratio ER ER 7.5 - ms
Average power of OFF transmitter - - - -30 dBm
Relative intensity noise RIN RIN - -128 dB/Hz
Eye mask Compliant with IEEE 802.3ae
Receiver
Centre wavelength λc 1480 - 1500 nm
Sensitivity Pmin - - -23 dBm
Sensitivity(SM 80km) Pmin - - -20 dbm
Receiver overload Pmax -6 - - dBm
LOS De-assert LOSD - - -24 dBm
LOS assert LOSA -38 - - dBm
LOS -hysteresis PHys -0.5 - 8 dB

SFP+ TRANSCEIVER ELECTRICAL PAD LAYOUT

PIN FUNCTION DEFINITIONS
Pin Name Function Plug Seq. Notes
1 VeeT Transmitter ground Note 5
2 TX Fault Transmitter fault indication Note 1
3 TX Disable Transmitter disable Note 2, module disables on high or open
4 SDA Module definition 2 2-Wire serial interface data line.
5 SCL Module definition 1 2-Wire serial interface clock.
6 MOD-ABS Module definition 0 Note 3
7 RS0 RX rate select(LVTTL). No function implement
8 LOS Loss of signal Note 4
9 RS1 TX Rate select(LVTTL). No function implement
10 VeeR Receiver ground Note 5
11 VeeR Receiver ground Note 5
12 RD- Inv. received data out 3 Note 6
13 RD+ Received data out 3 Note 6
14 VeeR Receiver ground Note 5
15 VccR Receiver power 3.3V ± 5%, Note 7
16 VccT Transmitter power 3.3V ± 5%, Note 7
17 VeeT Transmitter ground Note 5
18 TD+ Transmit data in Note 8
19 TD- Inv. transmit data in Note 8
20 VeeT Transmitter ground Note 5
Notes:
1) TX Fault is an open collector/drain output, which should be pulled up with a 4.7K – 10KΩ resistoron the host board. Pull up voltage between 2.0V and VccT/R+0.3V. When high, output indicates a laser fault of some kind. Low indicates normal operation. In the low state, the output will be pulled  to < 0.8V.

2) TX disable is an input that is used to shutdown the transmitter optical output. It is pulled up within the module with a 4.7K – 10 KΩ resistor. Its states are:
Low (0 – 0.8V): Transmitter on
 (>0.8, < 2.0V): Undefined
High (2.0 – 3.465V): Transmitter Disabled
Open: Transmitter Disabled

3) Module Absent, connected to VeeT or VeeR in the module.

4) RX LOS (Loss of Signal) is an open collector/drain output, which should be pulled up with a 4.7K
– 10KΩ resistor. Pull up voltage between 2.0V and VccT/R+0.3V. When high, this output indicates the received optical power is below the worst-case receiver sensitivity (as defined by the standard in use). Low indicates normal operation. In the low state, the output will be pulled to < 0.8V.

5) The module signal ground contacts, VeeR and VeeT, should be isolated from the module case.

6) RD-/+: These are the differential receiver outputs. They are AC coupled 100Ω differential lines   which should be terminated with 100Ω (differential) at the user SERDES. The AC coupling is done inside the module and is thus not required on the host board. The voltage swing on these lines will be between 120 and 800 mV differential (60 –400 mV single ended) when properly terminated.

7) VccR and VccT are the receiver and transmitter power supplies. They are defined as 3.3V ±5% at the SFP+ connector pin. Maximum supply current is 606mA. Recommended host board power  supply filtering is shown below. Inductors with DC resistance of less than 1 ohm should be used in order to maintain the required voltage at the SFP+ input pin with 3.3V supply voltage. When the recommended supply-filtering network is used, hot plugging of the SFP+ transceiver module will    result in an inrush current of no more than 30mA greater than the steady state value. VccR and VccT may be internally connected within the SFP+ transceiver module.

8) TD-/+: These are the differential transmitter inputs. They are AC-coupled, differential lines with  100Ω differential termination inside the module. The AC coupling is done inside the module and is thus not required on the host board. The inputs will accept differential swings of 150 – 1200 mV (75 – 600mV single-ended).

Performance Testing

Each module is tested before shipment to help ensure stable optical and electrical performance.

Compatibility Verification

Compatibility validation is available for major switch and router platforms.

Reliability Screening

Selected products support aging, temperature cycle, and stability testing for demanding applications.

Traceable Quality Control

Inspection and production records support more consistent quality control and batch traceability.

光模块产品详情订购信息---SFP+