




Generic Compatible 400G DR4 QSFP-DD 1310nm 500m DOM MPO8/12 SMF Optical Transceiver Module
QSFPDD-400(4×100)-13-05(DR4)-MPO8/12
- Broad Multi-Brand Compatibility
- Flexible Customization Support
- Tested for Reliable Performance
- Fast Response & Delivery
- Professional Technical Support
The FC-LINK QSFP-DD 400G (4x100G) 1310nm 500m DR4 MPO8/12 Transceiver is a high-performance 400Gb/s Quad Small Form Factor Pluggable-double density (QSFP-DD) optical module, ideal for optical communication applications over distances of up to 500m. The module converts 8 channels of 50Gb/s (PAM4) electrical input into 4 parallel optical signals, each supporting 100Gb/s, for a total data rate of 400Gb/s. On the receiver side, it reverses the process, converting 4 channels of 100Gb/s optical signals back into 8 channels of 50Gb/s (PAM4) electrical output.The module is compatible with MTP/MPO-12 connector optical fiber cables, ensuring precise alignment through guide pins inside the receptacle. To maintain proper channel-to-channel alignment, the cable should not be twisted. Electrical connectivity is achieved via an edge-type connector compliant with the QSFP-DD MSA standard.Designed with a compact form factor, robust optical and electrical connections, and a digital diagnostic interface, this transceiver is a reliable solution for high-speed, short-range data communication applications.
| SPECIFICATIONS | |||
|---|---|---|---|
| Product Model | QSFPDD-400(4x100)-13-05(DR4)-MPO8/12 | Manufacturer brand | FC-LINK |
| Package Type | QSFPDD | Optical connector | MPO 8C/12C |
| Max Data Rate | 400Gbps | Channel Data Rate | 53.125Gbps |
| Effective transmission distance | 500m | ||
| Wavelength | 1310nm | Operating voltage | 3.3V |
| Fiber Type | SMF | Core Size | 9/125 |
| Transmitter Type | VCSEL | Receiver Type | PIN |
| TX Power | -2.9~4.0dBm | Receiver Sensitivity | -4.4dBm |
| Digital Optical Monitoring(DOM) | YES | Receiver Overload | 4dBm |
| Power Consumption | <10W | Protocols | IEEE 802.3bs 400GBASE-DR4 400G Ethernet Infiniband interconnect Data center Enterprise Networking |
| Operating temperature(Commercial) | 0℃~+70℃ | Storage Temperature(Commercial) | -40℃~+85℃ |

Server-to-Switch Data Center Links
Used for 10G/25G/100G optical uplinks between servers and top-of-rack switches in high-density data center deployments.

Building-to-Building Campus Backbone
Suitable for 1G/10G fiber links between office buildings, campus distribution rooms, and backbone aggregation points.

Access-to-Core Enterprise Uplinks
Designed for switch uplinks from access to aggregation or core layers in enterprise and campus network architectures.

Industrial Switching in Harsh Environments
Applied in industrial Ethernet, automation systems, and outdoor cabinets where wider temperature tolerance and stable fiber communication are required.
| Absolute Maximum Ratings | |||||||||
| Parameter | Symbol | Min. | Max. | Unit | |||||
| Power supply voltage | VCC | -0.5 | 3.6 | V | |||||
| Storage temperature | TC | -40 | 85 | °C | |||||
| Relative humidity | RH | 0 | 85 | % | |||||
| These values represent the damage threshold of the module.Stress in excess of any of theindividual absolute maximum ratings can cause immediate catastrophic damage to the module even if all other parameters are within recommended operating conditions. | |||||||||
| Recommended Operating Environment | |||||||||
| Parameter | Symbol | Min. | Typical | Max | Unit | ||||
| Power supply voltage | VCC | 3.15 | 3.3 | 3.45 | V | ||||
| Operating case temperature | Tca | 0 | - | 70 | ℃ | ||||
| Recommended operating environment specifies parameters for which the electrical and optical characteristics hold unless otherwise noted. | |||||||||
| Electrical Characteristics | |||||||||
| Parameter | Symbol | Min | Typical | Max | Unit | Notes | |||
| Data rate per lane | DR | - | 53.125 | - | Gbps | - | |||
| Transmitter | |||||||||
| Input differential impedance | Rin | 90 | 100 | 110 | Ω | - | |||
| Differential input voltage swing | Vin | 900 | - | 1100 | mVp-p | - | |||
| Receiver | |||||||||
| Differential output swing | Vout | - | - | 900 | mVp-p | - | |||
| Output differential impedance | Rout | 90 | 100 | 110 | Ω | - | |||
| The following electrical characteristics are defined over the recommended operating environment unless otherwise specified. | |||||||||
| Optical Characteristics | |||||||||
| Parameter | Symbol | Min | Typical | Max | Unit | Notes | |||
| Transmitter | |||||||||
| Center wavelength | λ | 1304.5 | 1310 | 1317.5 | nm | - | |||
| Data rate,each lane | - | 53.125±100ppm | GBd | - | |||||
| Side-mode suppression ratio | SMSR | 30 | - | - | dB | - | |||
| Average optical power,per lane | Po | -2.9 | - | 4 | dBm | 1 | |||
| Extinction ratio | ER | 3.5 | - | - | dBm | - | |||
| Optical modulation amplitude | OMA | -4.5 | - | 3 | dB | - | |||
| Transmitter and dispersion eye closure | TDECQ | - | - | 3.4 | dB | - | |||
| Optical return loss tolerance | ORL | - | - | 21.4 | dB | - | |||
| Receiver | |||||||||
| CenterWavelength | λ | 1304.5 | 1310 | 1317.5 | nm | - | |||
| Data rate,each lane | - | 53.125±100ppm | GBd | - | |||||
| Average receive power,each lane | - | -5.9 | - | 4 | dBm | - | |||
| Receive power (OMAouter),each lane | - | - | - | 4.2 | dBm | - | |||
| Receiver sensitivity (OMAouter),each lane | - | - | - | -4.4 | dBm | - | |||
| LOS asserted | Lsa | -15 | - | - | dBm | - | |||
| LOS de-asserted | Lda | - | - | -8.9 | dBm | - | |||
| LOS hysteresis | Lh | 0.5 | - | - | dB | - | |||
| Note: [1]Average launch power,each lane(min)is informative and not the principal indicator of signal strength. [2]Atransmitter with launch power below this value cannot be compliant;however,avalue above this does not ensure compliance. | |||||||||
| The following optical characteristics are defined over the recommended operating environment unless otherwise specified. | |||||||||
| QSFP-DD Transceiver Electrical Pad Layout |
| Pin Definition | |||||||||
| Pad | Logic | Symbol | Name/Description | ||||||
| 1 | - | GND | Ground | ||||||
| 2 | CML-I | Tx2n | Transmitter inverted data input | ||||||
| 3 | CML-I | Tx2p | Transmitter non-inverted data input | ||||||
| 4 | - | GND | Ground | ||||||
| 5 | CML-I | Tx4n | Transmitter inverted data input | ||||||
| 6 | CML-I | Tx4p | Transmitter non-inverted data input | ||||||
| 7 | - | GND | Ground | ||||||
| 8 | LVTTL-I | ModSelL | Module select | ||||||
| 9 | LVTTL-I | ResetL | Module reset | ||||||
| 10 | - | Vcc Rx | +3.3V Power supply receiver | ||||||
| 11 | LVCMOS- I/O | SCL | 2-wire serial interface clock | ||||||
| 12 | LVCMOS- I/O | SDA | 2-wireserial interface data | ||||||
| 13 | - | GND | Ground | ||||||
| 14 | CML-O | Rx3p | Receiver non-inverted data output | ||||||
| 15 | CML-O | Rx3n | Receiver inverted data output | ||||||
| 16 | - | GND | Ground | ||||||
| 17 | CML-O | Rx1p | Receiver non-inverted data output | ||||||
| 18 | CML-O | Rx1n | Receiver inverted data output | ||||||
| 19 | - | GND | Ground | ||||||
| 20 | - | GND | Ground | ||||||
| 21 | CML-O | Rx2n | Receiver onverted data output | ||||||
| 22 | CML-O | Rx2p | Receiver non-inverted data output | ||||||
| 23 | - | GND | Ground | ||||||
| 24 | CML-O | Rx4n | Receiver inverted data output | ||||||
| 25 | CML-O | Rx4p | Receiver non-onverted data output | ||||||
| 26 | - | GND | Ground | ||||||
| 27 | LVTTL-O | ModPrsL | Module present | ||||||
| 28 | LVTTL-O | IntL | Interrupt | ||||||
| 29 | - | VCC Tx | +3.3V power supply transmitter | ||||||
| 30 | - | VCC1 | +3.3V power supply | ||||||
| 31 | LVTTL-I | InitMode | Initialization mode;in legacy QSFP applications,the initMode pad is called LPMODE | ||||||
| 32 | - | GND | Ground | ||||||
| 33 | CML-I | Tx3p | Transmitter non-inverted data input | ||||||
| 34 | CML-I | Tx3n | Transmitter inverted data input | ||||||
| 35 | - | GND | Ground | ||||||
| 36 | CML-I | Tx1p | Transmitter non-Inverted data input | ||||||
| 37 | CML-I | Tx1n | Transmitter inverted data input | ||||||
| 38 | - | GND | Ground | ||||||
| 39 | - | GND | Ground | ||||||
| 40 | CML-I | Tx6n | Transmitter inverted data input | ||||||
| 41 | CML-I | Tx6p | Transmitter non-inverted data input | ||||||
| 42 | - | GND | Ground | ||||||
| 43 | CML-I | Tx8n | Transmitter inverted data input | ||||||
| 44 | CML-I | Tx8p | Transmitter non-inverted data input | ||||||
| 45 | - | GND | Ground | ||||||
| 46 | - | Reserved | For future use | ||||||
| 47 | - | VS1 | Module vender specific1 | ||||||
| 48 | - | Vcc Rx1 | 3.3V power supply receiver | ||||||
| 49 | - | VS2 | Module vender specific2 | ||||||
| 50 | - | VS3 | Module vender specific3 | ||||||
| 51 | - | GND | Ground | ||||||
| 52 | CML-O | Rx7p | Receiver non-inverted data output | ||||||
| 53 | CML-O | Rx7n | Receiver inverted data output | ||||||
| 54 | - | GND | Ground | ||||||
| 55 | CML-O | Rx5p | Receiver non-inverted data output | ||||||
| 56 | CML-O | Rx5n | Receiver inverted data output | ||||||
| 57 | - | GND | Ground | ||||||
| 58 | - | GND | Ground | ||||||
| 59 | CML-O | Rx6n | Receiver inverted data output | ||||||
| 60 | CML-O | Rx6p | ReceiverNon-inverted data output | ||||||
| 61 | - | GND | Ground | ||||||
| 62 | CML-O | Rx8n | Receiver inverted data output | ||||||
| 63 | CML-O | Rx8p | Receiver non-inverted data output | ||||||
| 64 | - | GND | Ground | ||||||
| 65 | - | NC | No connect | ||||||
| 66 | - | Reserved | For futureuse | ||||||
| 67 | - | VCC Tx1 | 3.3V power supply transmitter | ||||||
| 68 | - | VCC2 | 3.3V power supply | ||||||
| 69 | - | Reserved | For future use | ||||||
| 70 | - | GND | Ground | ||||||
| 71 | CML-I | Tx7p | Transmitter non-inverted data input | ||||||
| 72 | CML-I | Tx7n | Transmitter inverted data input | ||||||
| 73 | - | GND | Ground | ||||||
| 74 | CML-I | Tx5p | Transmitter non-inverted data input | ||||||
| 75 | CML-I | Tx5n | Transmitter inverted data input | ||||||
| 76 | - | GND | Ground | ||||||

Performance Testing
Each module is tested before shipment to help ensure stable optical and electrical performance.

Compatibility Verification
Compatibility validation is available for major switch and router platforms.

Reliability Screening
Selected products support aging, temperature cycle, and stability testing for demanding applications.

Traceable Quality Control
Inspection and production records support more consistent quality control and batch traceability.
Related products
-

Generic Compatible 800G DR8 OSFP 500m DOM 2MPO8/12 SMF Optical Transceiver Module
OSFP-800(8x100G)-PAM4-05-(DR8)-MPO16/2MPO8/12
-

Generic Compatible 200GBASE-SR4 QSFP56 850nm 100m DOM MPO8/12 MMF Optical Transceiver Module
QSFP56-200-85-01(SR4)-MPO8/12
-

10G DWDM 50GHz SFP+ ER Transceiver for 40km SMF Links, Duplex LC
SFP+10-50DW-40(ER)-LCD
-

25G SFP28 BIDI LR Transceiver for 10km SMF Links, 1270/1330nm Simplex LC
SFP28BD-25-1213-10(LR)-LC















